How many net-metered solar installations does each California utility have? EIA counts
How many net-metered solar installations does each California utility have?
EIA’s 2025 Form EIA-861 data count 2,290,366 net-metered solar PV installations in California (2,241,381 residential), with 20,041.1 MW of capacity after EIA’s state adjustment to AC. Pacific Gas & Electric Co. reported 949,590, Southern California Edison Co 746,002 and San Diego Gas & Electric Co 346,738; the other 28 utilities with rows reported 248,036 combined.
From EIA’s 2025 Form EIA-861 net metering file, downloaded Nov 16, 2026. Counts are utility-reported, as of December 31, 2025.
Net-metered solar PV by utility, 2025
| Pacific Gas & Electric Co. | Investor Owned | 949,590 | 924,854 | 9,449.31 | AC | 178,468 |
| Southern California Edison Co | Investor Owned | 746,002 | 734,452 | 6,267.868 | AC | 130,848 |
| San Diego Gas & Electric Co | Investor Owned | 346,738 | 340,500 | 2,361.405 | AC | 10,687 |
| Los Angeles Department of Water & Power | Municipal | 97,727 | 95,898 | 745.215 | AC | 4,310 |
| Sacramento Municipal Util Dist | Political Subdivision | 64,626 | 62,657 | 423.393 | AC | 3,281 |
| City of Roseville - (CA) | Municipal | 13,476 | 13,362 | 62.258 | AC | 424 |
| Modesto Irrigation District | Political Subdivision | 12,254 | 11,986 | 95.713 | AC | 1,175 |
| Imperial Irrigation District | Political Subdivision | 12,078 | 11,728 | 163.208 | AC | 0 |
| City of Riverside - (CA) | Municipal | 8,248 | 7,975 | 79 | DC | 0 |
| Turlock Irrigation District | Political Subdivision | 5,613 | 5,415 | 71.514 | AC | 0 |
| City of Anaheim - (CA) | Municipal | 5,544 | 5,351 | 55.62 | DC | 0 |
| City of Glendale - (CA) | Municipal | 4,014 | 3,874 | 36.171 | AC | 343 |
| Merced Irrigation District | Political Subdivision | 3,699 | 3,623 | 25.906 | AC | 141 |
| City of Pasadena - (CA) | Municipal | 3,237 | 3,121 | 29.947 | AC | 0 |
| City of Moreno Valley - (CA) | Municipal | 3,225 | 3,204 | 20.363 | AC | 87 |
| City of Redding - (CA) | Municipal | 2,448 | 2,332 | 24.927 | DC | 0 |
| City of Burbank Water and Power - (CA) | Municipal | 1,989 | 1,899 | 18.012 | AC | 92 |
| City of Palo Alto - (CA) | Municipal | 1,891 | 1,763 | 21.6 | AC | 229 |
| City of Santa Clara - (CA) | Municipal | 1,347 | 1,233 | 24.527 | AC | 0 |
| City of Colton - (CA) | Municipal | 1,282 | 1,211 | 22.03 | AC | 26 |
| Alameda Municipal Power | Municipal | 1,264 | 1,235 | 7.473 | AC | 0 |
| PacifiCorp | Investor Owned | 1,109 | 995 | 15.896 | DC | 116 |
| Liberty Utilities | Investor Owned | 837 | 744 | 5.366 | AC | 60 |
| City of Lodi - (CA) | Municipal | 710 | 643 | 7.701 | AC | 0 |
| Bear Valley Electric Service | Investor Owned | 703 | 678 | 6.519 | DC | 0 |
| City of Azusa | Municipal | 476 | 464 | 4.564 | DC | 0 |
| City of Shasta Lake - (CA) | Municipal | 153 | 146 | 1.271 | AC | 4 |
| City of Vernon - (CA) | Municipal | 41 | 8.7 | AC | 0 | |
| City of Corona - (CA) | Municipal | 25 | 20 | 1.45 | AC | 0 |
| Surprise Valley Electrification | Cooperative | 20 | 18 | 0.184 | AC | 0 |
| City & County of San Francisco - (CA) | Municipal | 0 | 0 | AC | 0 |
From EIA’s Form EIA-861 2025 data files (downloaded Nov 16, 2026). EIA describes the net metering file this way: “The data contain cumulative installation count and capacity of generators that are net metered by technology, state, sector, and balancing authority.” Counts are utility-reported as of December 31, 2025, for each utility’s whole California service area. Unit is the capacity unit the utility reported, AC or DC; EIA’s utility rows are “reported as collected,” so DC and AC figures are not converted here. Blank cells are cells EIA printed as a period. EIA’s file notes: “All Technologies does not include batteries.”
California totals by month, 2026 (EIA-861M)
EIA’s monthly survey puts California at 2,334,680 net-metered PV customers in its preliminary figures for the latest month shown.
| Month | Data status | PV customers | Residential | PV capacity MW | PV-paired batteries |
|---|---|---|---|---|---|
| Jan 2026 | Preliminary | 2,254,488 | 2,206,861 | 20,143.008 | 339,469 |
| Feb 2026 | Preliminary | 2,265,232 | 2,217,397 | 20,291.166 | 348,599 |
| Mar 2026 | Preliminary | 2,277,320 | 2,229,108 | 20,444.777 | 356,544 |
| Apr 2026 | Preliminary | 2,290,515 | 2,241,779 | 20,660.255 | 366,515 |
| May 2026 | Preliminary | 2,300,657 | 2,251,620 | 20,786.379 | 374,096 |
| Jun 2026 | Preliminary | 2,311,309 | 2,261,946 | 20,956.781 | 382,215 |
| Jul 2026 | Preliminary | 2,322,212 | 2,272,639 | 21,079.17 | 390,937 |
| Aug 2026 | Preliminary | 2,334,680 | 2,284,759 | 21,245.024 | 398,780 |
From EIA’s EIA-861M net metering workbook for 2026, with the data status EIA prints on each row. Monthly figures come from EIA’s monthly survey and can differ from the annual Form EIA-861 numbers.
EIA’s definitions and caveats, quoted
From the Form EIA-861 instructions (Schedule 7, Part A), included in EIA’s 2025 zip:
“Net Metering tariff arrangements permit a facility, typically generating electricity from a renewable resource (using a meter that reads inflows and outflows of electricity) to sell excess power generated over its load requirement back to the electrical grid, typically but not necessarily at a rate equivalent to the retail price of electricity.”
“Virtual Net Metering: A billing arrangement that allows multiple energy customers to receive net metering credit from a shared onsite or remote renewable energy system as if it was located behind the customer’s own meter.”
“Report the number of net metering installations/customers that are actively enrolled in a net metering program as of December 31st of the data year.”
From EIA’s description of the files on the EIA-861 data page:
“The data contain cumulative installation count and capacity of generators that are net metered by technology, state, sector, and balancing authority. … We make a state-level adjustment for missing PV capacity and to convert state total capacity to AC units for those respondents who report data in DC units; we use 0.8256 as a conversion factor to change DC to AC.”
“The data contain cumulative values of generators that are not net metered and are under 1 megawatt in size (and not reported on Form EIA-860 ). … Form EIA-861S respondents do not provide non-net-metering distributed data.”
The note printed under the 2025 net metering sheet:
“Note: Data is reported as collected. Adjustments remove capacity lost in conversion from DC to AC and include PV capacity from the short form. All Technologies does not include batteries. Some utilities reclassified net metering as non net metering distributed, or vice versa. Source: U.S. Energy Information Administration, Form EIA-861, 'Annual Electric Power Industry Report.'”
The note printed under the 2026 EIA-861M net metering sheet:
“Note: In August 2023 the collection of storage data was discontinued and PV paired and PV non-paired battery data began. NM = Not Meaningful due to large relative standard error. Data is reported as collected. All Technologies does not include batteries. Adjustments add capacity for non-respondents and remove capacity lost in conversion from DC to AC. The adjusted capacity values reported in the adjustments are for net metering and virtual net metering < 1 MW combined. Some utilities reclassified net metering as non net metering distributed, or vice versa. Source: U.S. Energy Information Administration, Form EIA-861M, 'Monthly Electric Power Industry Report.'”
Common questions
How does EIA define net metering?
In the Form EIA-861 instructions: “Net Metering tariff arrangements permit a facility, typically generating electricity from a renewable resource (using a meter that reads inflows and outflows of electricity) to sell excess power generated over its load requirement back to the electrical grid, typically but not necessarily at a rate equivalent to the retail price of electricity.”
Why does this differ from the installs counted elsewhere on this site?
This site’s installer pages count residential interconnections in the PG&E, SCE and SDG&E records (DG Stats). EIA counts every sector at every California utility that files net metering data, as enrolled on December 31, 2025.
Is the state total the sum of the utility rows?
For the count, yes: the 31 utility rows add up to EIA’s state figure of 2,290,366. For capacity, no: EIA’s file note says its adjustments “remove capacity lost in conversion from DC to AC and include PV capacity from the short form.”
Sources
- U.S. Energy Information Administration: Form EIA-861, Annual Electric Power Industry Report, detailed data files
- U.S. Energy Information Administration: Form EIA-861M, Monthly Electric Power Industry Report, net metering file
Records last pulled Nov 16, 2026. Every entry links to the original public record.